File #: 24-498    Version: 1 Name: Rezoning Application - 903 Admirals Rd - Staff Report No. DRC-24-009
Type: Staff Report Status: Agenda Ready
File created: 11/5/2024 In control: APC Design Review Committee
On agenda: 11/13/2024 Final action:
Title: Rezoning Application - 903 Admirals Rd - Staff Report No. DRC-24-009
Attachments: 1. APPENDIX A: Aerial Map, 2. APPENDIX B: Site Survey, 3. APPENDIX C: Architectural Plans, 4. APPENDIX D: Landscaping Plans, 5. APPENDIX E: Tree Management Plan, 6. APPENDIX F: Green Building Checklist, 7. APPENDIX G: Site Servicing Plan

REQUEST FOR DECISION

 

DATE:                       November 13, 2024                     Report No. DRC-24-009

TO:                       Chair and Members of the Advisory Planning Commission Design Review Committee

FROM:                      James Davison, Manager of Development Services

SUBJECT:

 

Title

Rezoning Application - 903 Admirals Rd - Staff Report No. DRC-24-009End

 

RECOMMENDATION:

 

Recommendation

That the Esquimalt Design Review Committee recommends to Council to either approve, approve with conditions, or deny the rezoning which would allow the construction of eight townhouse units on the property.

Body

RELEVANT POLICY:

 

Official Community Plan Bylaw, 2018, No. 2922

Zoning Bylaw, 1992, No. 2050

Local Government Act

Declaration of Climate Emergency

Parking Bylaw, 1992, No. 2011

Development Application Procedures and Fees Bylaw, 2012, No. 2791

Advisory Planning Commission Bylaw, 2012, No. 2792

Subdivision and Development Control Bylaw, 1997, No. 2175

Green Building Checklist

 

STRATEGIC RELEVANCE:

 

Housing

 

BACKGROUND:

 

Appendix A: Aerial Map

Appendix B: Site Survey

Appendix C: Architectural Plans

Appendix D: Landscaping Plans

Appendix E: Tree Management Plan

Appendix F: Green Building Checklist

Appendix G: Site Servicing Plan

 

PURPOSE OF APPLICATION:

 

The application proposes the rezoning of the subject property from RS-2: Single Family Panhandle Residential to a CD zone which will permit eight townhouses at an FSR of 0.59.

 

CONTEXT:

 

Applicant: Vijay Banghu, Ramtard Developments

 

Owner: 1408613 B.C. LTD., INC.NO. BC1408613

 

Designer: Adapt Design

 

Property Size: 1,739m2

 

OCP Land Use Designation:

Current:  Townhouse Residential

Proposed: Townhouse Residential

 

Existing Zone: RS-2 Single Family Panhandle Residential

Proposed Zone: CD Zone

 

Existing Land Use: Single Family Residential                     

Proposed Land Use: Townhouse Residential

 

Surrounding Land Uses:

North: Townhouse Residential

South: Townhouse Residential

East: Mix of Townhouse Residential, Single Family and Duplex Residential

West: Townhouse Residential

 

OCP ANALYSIS:

 

The application is consistent with the Townhouse Residential Land Use Designation within the Official Community Plan. As such, a Public Hearing will not be required.

 

ZONING ANALYSIS:

 

Lot Area: 1,739m2

Floor Area: 1,024m2

Floor Space Ratio (FSR) 0.59

Lot Coverage: 32%

 

Front Yard Setback: 5m

Side Yard Setback (N): 4m

Rear Setback: 4m

Side Yard Setback (S): 4m

 

Useable Open Space: None provided (dimension must be 6m in shortest direction)

 

PARKING ANALYSIS:

 

Parking provided is two spaces per townhouse unit, plus two visitor spaces within the driveway. The visitor parking spaces leave 3m of drive aisle in the driveway, which will accommodate one vehicle width.

 

Parking Bylaw, 1992, No. 2011 requires two spaces per dwelling unit, and one out of every four required parking spaces must be designated for visitors. The proposal exceeds the requirements of the current parking bylaw.

 

TREE ANALYSIS:

 

A Tree Management Plan is attached to the report as Appendix E. None of the existing protected trees onsite will be retained. The report indicates that none of the offsite trees will be affected, and 81 new trees will be required as replacements.

 

COMMENTS FROM OTHER DEPARTMENTS:

 

Pending

 

ISSUES: 

 

Please consider the proposed uses, massing, height, lot coverage, setbacks, number of units, unit sizes, amount of open space, relationship to nearby land uses, and number of parking spaces.

 

ALTERNATIVES:

 

1. the Advisory Planning Commission Design Review Committee recommends to Council that the rezoning application be approved including reasons for this recommendation.

 

2.  That the Advisory Planning Commission Design Review Committee recommends to Council that the rezoning application be approved subject to conditions, including reasons for this recommendation.

 

3  That the Advisory Planning Commission Design Review Committee recommends to Council that the rezoning application be denied including reasons for this recommendation.